varmeks.com

Varm Boost Series 15 kW

  • The Varm Boost series, equipped with environmentally friendly R290 gas, features an A+++ energy label.
  • The Varm Boost series offers heating, cooling, and domestic hot water modes.
  • It can operate in ambient temperatures down to -25°C. Enjoy user convenience with the colored LCD panel.
Varmeks ModelVM-0MB1402015
Heating Condition – Ambient Temp.(DB/WB): 7/6 °C,Water Temp.(In/Out):30/35 °C
Heating Capacity Range (kW)5.9~14.8
Heating Power Input Range(kW)0.85~2.95
COP Range3.86~5.29
DHW Condition-Ambient Temp.(DB/WB): 7/6 °C,Water Temp.(In/Out):15/55 °C
Heating Capacity Range (kW)5.2~10.2
Heating Power Input Range(kW)1.10~2.87
COP Range3.55~4.71
Heated water output (L/H)219
Cooling Condition – Ambient Temp.(DB/WB):35/24 °C,Water Temp.(In/Out):12/7 °C
Cooling Capacity Range (kW)3.3~8.2
Cooling Power Input Range(kW)1.08~3.07
EER Range2.67~3.06

 

 

 

Space Heating (According to EN14825:2022)

Average Climate Water Outlet 35°C

Rated heat output (kW)7,89
Seasonal Space Heating Energy Efficiency (ns)181.0%
Seasonal Space Heating Energy Efficiency (SCOP)4,6
ErP LevelA+++
Sound pressure level (dB(A)) at 1 meter43
Sound power level (dB(A))57

 

 

 

Space Heating (According to EN14825:2022)

Average Climate Water Outlet 55°C

Rated heat output (kW)8,7
Seasonal Space Heating Energy Efficiency (ns)137.0%
Seasonal Space Heating Energy Efficiency (SCOP)3,5
ErP LevelA++
Sound pressure level (dB(A)) at 1 meter47
Sound power level (dB(A))61
Power supply230V/1Ph/50 Hz/60 Hz
Max. power input (kW)4,1
Max. current (A)18,8
Fuse or circuit breaker (A)25
Wire diameter mm²4
Diameter of pipe (mm)DN25
Water Flow (m3/h)1,96
Water Pressure Drop (max) kPa35
Net Weight (kg)120
Body size (W*D*H) (mm)1080×460×960
IP Grade (Level of protection)IPX4
Anti-electric shock RateI
Refrigerant R290/0.95 kg
CompressorBrandHIGHLY
Water pumpBrandSHIMGE